kw.\*:("Appareillage protection")
Results 1 to 25 of 1236
Selection :
Arc modelling in circuit breakers: coupling between electromagnetics and fluid mechanicsVERITE, J. C; BOUCHER, T; COMTE, A et al.IEEE transactions on magnetics. 1995, Vol 31, Num 3, pp 1843-1848, issn 0018-9464, 1Conference Paper
Einsatz von NH-Sicherungs-Lasttrennschaltern = Loading of NH-security switch isolatorsRÜBSAM, Hans J.TAB. Technik am Bau. 2002, Num 11, pp 49-56, issn 0341-2032, 7 p.Article
Bibliography of relay literature, 1992SACHDEV, M. S; FOLKMAN, A. G; KEZUNOVIC, M et al.IEEE transactions on power delivery. 1995, Vol 10, Num 1, pp 142-152, issn 0885-8977Conference Paper
Bibliography of metal oxide surge arresters, 1990-1992THALLAM, R. S; KOEPFINGER, J. L; ODENBERG, R et al.IEEE transactions on power delivery. 1995, Vol 10, Num 3, pp 1285-1300, issn 0885-8977Conference Paper
A new directional element for numerical distance relays. DiscussionMCLAREN, P. G; SWIFT, G. W; ZHANG, Z et al.IEEE transactions on power delivery. 1995, Vol 10, Num 2, pp 666-675, issn 0885-8977Conference Paper
A survey of optical channels for protective relaying practices and experience: a report prepared by working group H-2 of the relaying communications subcommittee of the IEEE power system relaying committeeHUDDLESTON, J. D; PHILIPPE, T. A; MICHEL, G. L et al.IEEE transactions on power delivery. 1995, Vol 10, Num 2, pp 647-658, issn 0885-8977Conference Paper
Study of inequallly spaced grounding gridsHUANG, L; CHEN, X; YAN, H et al.IEEE transactions on power delivery. 1995, Vol 10, Num 2, pp 716-722, issn 0885-8977Conference Paper
Concepts of undervoltage load shedding for voltage stability. DiscussionTAYLOR, C. W; HENVILLE, C. F; MITTELSTADT, W. A et al.TAYLOR, C. W; IEEE transactions on power delivery. 1992, Vol 7, Num 2, pp 480-488, issn 0885-8977Conference Paper
Impulse impedance of rectangular grounding gridsGUPTA, B. R; SINGH, V. K.IEEE transactions on power delivery. 1992, Vol 7, Num 1, pp 214-218, issn 0885-8977Conference Paper
Recent development of digital protective relaying equipmentKUBO, T; SANO, Y; WATANABE, A et al.Hitachi review. 1984, Vol 33, Num 3, pp 151-156, issn 0018-277XArticle
Circuit breaker model for digital simulation based on Mayr's and Cassie's differential arc equationsBIZJAK, G; ZUNKO, P; POVH, D et al.IEEE transactions on power delivery. 1995, Vol 10, Num 3, pp 1310-1315, issn 0885-8977Conference Paper
Grounding resistance of buried electrodes in multi-layer earth predicted by simple voltage measurement along earth surface: a theoretical discussion. DiscussionCHOW, Y. L; YANG, J. J; SRIVASTAVA, K. D et al.IEEE transactions on power delivery. 1995, Vol 10, Num 2, pp 707-715, issn 0885-8977Conference Paper
L'électronique de puissance dans les moyens d'essais = Power electronics in test equipmentsMIGUAISE, J. F; COURAULT, J.Revue générale de l'électricité (Paris). 1992, Num 6, pp 79-84, issn 0035-3116Article
The effect of reducing momentary outages on distribution reliability indices : 1991 Transmission and distribution conferenceWARREN, C. M.IEEE transactions on power delivery. 1992, Vol 7, Num 3, pp 1610-1617, issn 0885-8977Conference Paper
DYNA-TEST simulator for relay testing. I : Design CharacteristicsKEZUNOVIC, M; ABUR, A; KOJOVIC, L et al.IEEE transactions on power delivery. 1991, Vol 6, Num 4, pp 1423-1429, issn 0885-8977Conference Paper
Discover relay design and application problems using pseudo-transient tests. DiscussionHENVILLE, C. F; JODICE, J. A.IEEE transactions on power delivery. 1991, Vol 6, Num 4, pp 1444-1452, issn 0885-8977Conference Paper
Expert system for designing transmission line protection systemKAWAHARA, K; SASAKI, H; KUBOKAWA, J et al.Electrical power & energy systems. 1995, Vol 17, Num 1, pp 69-78, issn 0142-0615Article
Match customer service to need for reliability, qualityREASON, J.Electrical world. 1995, Vol 209, Num 4, pp 19-26, issn 0013-4457, 6 p.Article
Relay database designMCLAIN, J; CHAN, S. M; CHOE, D et al.IEEE computer applications in power. 1995, Vol 8, Num 3, pp 16-20, issn 0895-0156Article
Un pas décisif dans la protection des centrales grâce au disjoncteur d'alternateur au SF6, FKG = A decisive enhancement step in power plant protection thanks to FKG, the alternator SF6 circuit breakerBIQUEZ, F; GERREBOO, F. O; WILLIEME, J. M et al.Revue T&D. 1995, Num 1, pp 4-9, issn 1265-7948Article
Power line carrier practices and experiences: a report by the power line carrier practices working group of the power system relaying commmitteeHOHN, J. W; ZIPP, J. A; OHNESORGE, R. W et al.IEEE transactions on power delivery. 1995, Vol 10, Num 2, pp 639-646, issn 0885-8977Conference Paper
Predicting the optimum routine test interval for protective relays. DiscussionKUMM, J. J; WEBER, M. S; HOU, D et al.IEEE transactions on power delivery. 1995, Vol 10, Num 2, pp 659-665, issn 0885-8977Conference Paper
A microprocessor-based scheme for testing protective relaysSHENOY, U. J; FAKRUDDIN, D. B; PARTHASARATHY, K et al.Electric machines and power systems. 1985, Vol 10, Num 2-3, pp 119-128, issn 0731-356XArticle
Summary of «System protection and voltage stability»: a summary of a special publication prepared by the protection aids to voltage stability working group of the substation protection subcommittee of the IEEE power system relaying committee. DiscussionBEGOVIC, M; FULTON, D; POSTFOROOSH, J et al.IEEE transactions on power delivery. 1995, Vol 10, Num 2, pp 631-638, issn 0885-8977Conference Paper
Nouveau disjoncteudr à SF6 de 24 à 38 kV pour l'extérieur = New 24-to-38 kV SF6 circuit breaker for ouward installationHUX, G.Revue T&D. 1994, Num 1, pp 15-17, issn 1265-7948Article